DuPont SFP-2860 High-efficiency Ultrafiltration Membrane For Industrial water treatment
Datos del producto:
Lugar de origen: | PORCELANA |
Nombre de la marca: | DuPont |
Certificación: | CE |
Número de modelo: | SFP-2860 |
Documento: | UF-IntegraTec-P-Series-PVDF...en.pdf |
Pago y Envío Términos:
Cantidad de orden mínima: | 1 PC |
---|---|
Precio: | Negociable |
Detalles de empaquetado: | Embalaje de exportación estándar |
Tiempo de entrega: | 5- 8 días de trabajo |
Capacidad de la fuente: | 60000 unidades por mes |
Información detallada |
|||
Área de membrana 2860: | 51 m² (549 ft²) | Rango de flujo 2860 (25°C): | 40–90 lmh |
---|---|---|---|
2860 TMP máx.: | 2.1 barra | 2860 Caudal: | 2.0–6.9 m³/hr |
2860 Peso (Vacío): | 48 kg | Aplicaciones principales: | Pretratamiento para sistemas RO |
Descripción de producto
Product Overview
The DuPont™ SFP-2860 is an 8-inch, externally-fed hollow fiber ultrafiltration (UF) membrane module designed for high-flow water treatment systems . It is engineered with high-strength, hydrophilic PVDF (Polyvinylidene Fluoride) membrane fibers to ensure long service life, reliable performance, and reduced operating costs .
Key Features & Benefits:
-
High Filtration Efficiency: A nominal pore size of 0.03 µm effectively removes bacteria, viruses, and particulate matter, including colloids, providing excellent protection for downstream processes like Reverse Osmosis (RO) systems .
-
Durable Material: The PVDF hollow fiber membrane offers high mechanical strength and strong chemical resistance, ensuring a longer lifespan and stable performance even under harsh cleaning conditions .
-
External Pressure Design: This structure allows it to handle higher feed suspended solids concentrations, reducing pre-treatment requirements and minimizing backwash water volume .
-
Cost-Effective Design: The large 8-inch diameter and 51 m² effective membrane area provide an economical design for larger systems . The U-PVC membrane shell eliminates the need for expensive pressure vessels
Attribute | Value |
---|---|
Membrane Area | 51 m² (549 ft²) |
Flux Range (25°C) | 40–90 LMH |
Max TMP | 2.1 bar |
Flow Rate | 2.0–6.9 m³/hr |
Weight (Empty) | 48kg |
Target Applications | Industrial wastewater reuse, Seawater pretreatment for desalination, Compact containerized plants, Cooling tower blowdown recovery |
Parameter | SI Units | US Units |
---|---|---|
Filtrate Flux @ 25ºC | 40-120 l/m2/hr | 24-70 gfd |
Flow range | 2.0 - 6.1 m3/hr | 9.2 - 26.7 gpm |
Temperature | 1-40ºC | 34-104ºF |
Max. inlet module pressure (@ 20ºC) | 6.25 bar | 93.75 psi |
Max. operating TMP | 2.1 bar | 30 psi |
Max operating air scour flow | 12 nm3/hr | 7.1 scfm |
Max backwash pressure | 2.5 bar | 36 psi |
Operating pH | 2-11 |
- Filtrate turbidity ≤0.1 NTU
- Filtrate SDI ≤2.5
Proper start-up of a UF system is indispensable for preparing the membranes for operational service and preventing membrane damage. Adhering to the correct start-up sequence also contributes to ensuring that the operating parameters of the system conform to the design specifications.
Before commencing the system start-up procedures, membrane pretreatment, installation of the membrane modules, instrument calibration, and other system checks should be accomplished. Kindly refer to the product technical manual.